Ophthalmology optical coherence tomography scanner mocean4000

The vascular imaging technology (OCTA) based on optical coherence tomography is a non-invasive and fast blood flow detection technology. Currently, it is mainly used for blood flow imaging of the retinal choroid. OCTA can detect and quantitatively analyze blood flow signals without intravenous injection of contrast agent, and can observe and judge the changes in blood flow of the retinal choroid in layers. High-speed imaging, large scanning range, powerful functions and glaucoma analysis functions


Product Advantages

1. 80,000 A-scan/s high-speed imaging + 100 OCT images high-definition superimposition 100 OCT images high-definition superimposition 12 depths

Deep choroid imaging (DCI)

212 (1)
212 (2)

2. Large-scale real-time SLO fundus imaging,

Real-time eye tracking Mocean 4000 can acquire 47 large-scale fundus images and high-definition OCT images in real time, and the lesion area can be easily found before acquisition. The average superposition of 50 SLO fundus images provides high-definition fundus images with enhanced signal-to-noise ratio and clearer imaging. SLO-based eye tracking can reduce artifacts caused by eye drift and micro saccades. It performs 100 tracking per second, with a tracking accuracy of 10 microns and a success rate of more than 95%, which is an ideal solution for patients with less cooperation

3. Quantitative analysis of the new school network

Macular area: blood vessel density perfusion density / FAZ / non-perfusion area / blood flow area optic disc area vascular density perfusion density

212 (3)
212 (4)

4. 16mm wide-range angle scan and data analysis

5. Analysis of upper corneal thickness

Mocean 4000 provides a 6mm corneal epithelial thickness map, which is an important part of refractive surgery diagnosis and has important clinical application value

212 (5)

Technical Parameter

Way

Frequency domain OCT

light source

Super Light Emitting Diode (SLD), 840 nm

Scan speed

80,000 A-scans/sec

Axial resolution

5μm (optical), 2.7μm (digital)

Horizontal resolution

15μm (optical), 3 μm (digital)

Scan depth

3 mm

Refractive compensation range

-20 D ~ +20 D

Scan mode

Macula: HD linear scan (6 mm or 12 mm), area scan (6 mm x 6 mm), six-line scan, ten-line scan

OCTA scan density

Disc: area scan (6 mm x 6 mm)

OCTA scan range

Anterior section: HD linear scan (6 mm or 16mm), six-line scan

Way

256 x 256 A-scans or 360 x 360 A-scans or 360 x 540 A-scans

Minimum pupil diameter

3mm x 3 mm, 6 mm x 6 mm, 8mm x 8 mm, 12mm x 8mm

visual field

Line scan ophthalmoscope (LSO)

Macula

3.0 mm

glaucoma

47°

Anterior section

Retinal thickness analysis; 3D view; en-face analysis; progressive analysis; deep choroidal imaging

Connect function

Retinal nerve fiber layer analysis; ganglion cell analysis; cup-disc surface analysis; glaucoma follow-up analysis; binocular contrast analysis

weight

Manual measurement; corneal thickness analysis; corneal epithelial layer thickness analysis

volume

Comply with DICOM standard; optional remote

Voltage frequency

30.5 kg